What was found
RETRACTING LANDING GEAR, GEAR INTRANSIT LIGHT WOULD NOT EXTINGUISH AND HYD PUMP KEPT RUNNING. DIVERTED, PERFORMED QRH AND EXTENDED LANDING GEAR NOSE WHEEL TOOK EXCESSIVE TIME COMING DOWN. PREVIOUSLY SUBMITTED OPEN CONTROL NR 2014FA0000678. PERFORMED VISUAL INSPECTION ON ALL LANDING GEAR COMPONENTS, CLEANED LANDING GEAR UPLOCK SWITCHES AND PERFORMED OPS CHECK FOR LANDING GEAR. EXTENSION AND RETRACTION MULTIPLE TIMES, NO DEFECTS NOTED.