What was found
FLIGHT: 65 GGT/FLL AFTER SELECTING GEAR HANDLE DOWN IT TOOK BETWEEN 20 TO 30 SECONDS BEFORE THEY WERE OUT AND LOCKED, PUMP WAS RUNNING THE WHOLE TIME. CORRECTIVE ACTION: PERFORMED HYDRAULIC SYSTEM SERVICING PERFORMED EXTENSION AND RETRACTION OF LANDING GEARS OPERATIONAL CHECK NORMAL NO DEFECT NOTED.