What was found
DAMAGE WAS FOUND TO THE FRAME 5 (P/N: L533M1088219/L533M1105219) IN THE FORM OF CRACKS. THERE ARE FOUR CRACKS TO BOTH THE L/H AND R/H FRAME NEAR THE UPPER AND LOWER MOST POINTS WHERE THE MEDICAL INTERIOR BEAM ATTACHES. THE LONGEST CRACK MEASURED TO BE APPROXIMATELY 1.625" ON THE FWD L/H SIDE OF THE FRAME 5 UPPER MOUNT LOCATION OF THE MEDICAL WALL. CRACKS WERE ALSO DISCOVERED ON BOTH L/H AND R/H FRAME 5 ANGLES (P/N: L533M1088218/L533M1105218) AT THE AFT INBOARD LOWER ATTACHMENT POINT OF THE MEDICAL STC. THE L/H ANGLE CRACKED MEASURED APPROXIMATELY 1.05", WITH THE R/H CRACK MEASURING 1.0" IN LENGTH