What was found
DURING A SCHEDULED INSPECTION REQUIRED BY AIR METHODS ASB21-01, DAMAGE WAS DISCOVERED AT FRAME 5 AT APPROXIMATELY FS 4,709MM. THE DAMAGE IS ADJACENT TO THE MEDICAL WALL LOWER RH & LH AND UPPER LH, CENTER, AND RH ATTACH FITTING LOCATIONS. THE MEDICAL WALL IS A PART OF THE AIR METHODS STC # SR00556DE INSTALLED ON FAA FORM 337 DATED 06 FEB 2009.
THE DESCRIPTION OF DAMAGE, SUBSTANTIATING DATA, AND REPAIR PROCEDURES PERFORMED ARE DOCUMENTED IN AIR METHODS ALERT SERVICE BULLETIN ASB21-01, REVISION A DATED 08 NOV 2021 AND IS FAA APPROVED DATA.