What was found
ACFT RETURNED, DUE TO ACFT CROSS TIE AND RT GENERATOR FAILED. CAPTAIN REPORTED THAT THE LANDING WAS WITH EMERGENCY POWER AND WITHOUT FLAPS/SLATS EXTENDED, MAINT PERFORMED AC CROSS TIE AND RT GENERATOR TEST IAW AMM 24-20-00, ALL CORRECT. FLAPS/SLATS CONTROL SYS WAS TESTED IAW AMM 27-50-00 ALL CORRECT. THE OVERWEIGHT INSP WAS PERFORMED IAW AMM 05-51-04, NO DAMAGES WERE FOUND.