What was found
DURING THE MX INSP, 3 BLADES OF THE HPC 1ST STAGE WITH DENT ON L/E OUT OF LIMITS IN THE LT ENGINE IAW MM 72-00-00 WITH DIMENSIONS OF 2.3750 INCHES LENGTH, 1 INCH DEPTH, .6250 INCH FROM TIP; 2.5 INCHES LENGTH, 1 INCH DEPTH, 1 INCH FROM TIP AND 2 INCHES LENGTH, .5 INCH DEPTH, 1 INCH FROM TIP. MX PERSONNEL REPLACED THE BLADES AND TESTED THE LT ENGINE IAW MM 72-21-00, MM 72-23-01 AND MM 72-363-21, ALL CORRECT.