As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A TAKEOFF ROLL, PILOT HEARD A POP AND THE ACFT PULLED HARD TO THE LT AND LEFT THE RUNWAY AND ENDED UPSIDE DOWN. THE LEFT MLG FORWARDED ATTACH BOLT BROKE AND ALLOWED THE LT MLG TO COME LOOSE AND CAUSED THE LEFT "PULL" OF THE ACFT. THIS BOLT ACCORDING TO THE ACFT RECORDS HAD 1553 HOURS TIME IN SERVICE. THE MFG RECOMMENDS A REPLACEMENT OF 600- 1000 HOURS TIME IN SERVICE FOR THIS BOLT.