As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFTER TAKEOFF & DURING CLIMB OUT, THE PRIMARY HYDRAULICS BEGAN TO FLUCTUATE. THE MASTER CAUTION & PRIMARY HYD LIGHT ILLUMINATED. EMERGENCY PROCEDURES PERFORMED. LANDED ACFT WITH NO INCIDENT. R & R BLOWN PRIMARY HYD HOSE, PN SS40CT6C206000. LEAK CHECKS WERE PERFORMED. NO LEAKS WERE DETECTED.