What was found
DURING INSPECTION OF VERTICAL PRESSURE WEB AT BS 663, FOUND TWO CRACKS 1.5 INCHES LONG AT LBL 41, WL 194 AND 1.5 INCHES LONG AT LBL 43, WL 197. REPAIRED VERTICAL PRESSURE WEB IAW SRM 57-10-10. REPAIR NR 3, ALTERNATE NR 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION OF VERTICAL PRESSURE WEB AT BS 663, FOUND TWO CRACKS 1.5 INCHES LONG AT LBL 41, WL 194 AND 1.5 INCHES LONG AT LBL 43, WL 197. REPAIRED VERTICAL PRESSURE WEB IAW SRM 57-10-10. REPAIR NR 3, ALTERNATE NR 2.