What was found
DURING INSPECTION, FOUND 15 INCH CRACK IN BS 663 VAPOR WEB FIBERGLASS PANEL BETWEEN LBL 29 - 40, BETWEEN WL 148 - 161. REPAIRED CRACK IAW SRM 51-70-04, REPAIR 10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION, FOUND 15 INCH CRACK IN BS 663 VAPOR WEB FIBERGLASS PANEL BETWEEN LBL 29 - 40, BETWEEN WL 148 - 161. REPAIRED CRACK IAW SRM 51-70-04, REPAIR 10.