Service difficulty report · Circuit Breaker · Cessna 441

Difficulty date
July 3, 2021
Submitted
July 6, 2021
Operation
Air carrier
Aircraft
N11MM
Make and model
Cessna 441
Aircraft serial
4410105
Aircraft time
10,255 hours, 7,957 cycles
Engine
Garrtt TPE33110N
Part
Circuit Breaker
Part number
CM35897
Condition
Failed
Location
Cockpit
Part time
10,225 hours, 7,957 cycles
Component
None
Stage of operation
TX
How discovered
O
Nature of condition
B
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING TAXI-OUT FROM BASE, CAPT. NOTED SMOKE EMITTING FROM LIGHT SWITCH AREA AT THE LOWER LH CONSOLE. THEY TAXIIED BACK HOME BASE UNEVENTFULLY AND HANDED OVER THE AIRCRAFT TO MAINTENANCE. IT WAS IMMEDIATELY APPARENT THAT THE RH STROBE LIGHT CIRCUIT BREAKER SWITCH DID NOT SHUT THE STROBE LIGHTS OFF WHEN ACTUATED WITH THE BATTERY ON. BATTERIES WERE DISCONNECTED AND AN INSPECTION OF THE RH STROBE LIGHT SYSTEM WAS CONDUCTED. SEVERAL WIRES ALONG THE LENGTH OF THE CIRCUIT WERE DARK WITH A BURNT SMELL, AND A CHAFE TO GROUND WAS NOTED AT THE WINGTIP CONNECTOR TO THE STROBE LIGHTS. THE CB SWITCH WAS SLIGHTLY BULGED FROM OVERHEATING WITH A BURNT SMELL. NO OTHER SYSTEMS WERE MALFUNCTIONING, AND THE AFFECTED WIRES DID NO APPARENT DAMAGE TO THE SURROUNDING WIRING OR COMPONENTS. THE AFFECTED WIRING WAS REPAIRED OR REPLACED PER MM PRACTICES, ENSURING PROPER CLEARANACE AND CHAFE PROTECTION. THE AFFECTED 7 AMP CIRCUIT BREAKER SWITCH WAS REPLACED, AND A SATISFACTORY OPERATIONAL CHECK WAS PERFORMED. TOTAL TIME ON THE AFFECTED CIRCUIT BREAKER SWITCH COULD NOT BE DETERMINED, AND IS ASSUMED TO BE ORIGINAL.

More about the Cessna 441