Service difficulty report · Switch Panel · Emb EMB135ER

Difficulty date
April 21, 2023
Submitted
May 22, 2023
Operation
Air carrier
Aircraft
N268JX
Make and model
Emb EMB135ER
Aircraft serial
145499
Aircraft time
16,452 hours, 15,689 cycles
Part
Switch Panel
Part number
14521325405
Part serial
145213
Condition
Failed
Stage of operation
CL
How discovered
V
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ISSUE-CREW REPORTED LOSS OF ALL GENERATORS, ISIS, ALL SCREENS EXCEPT PFD1, PFD1 HAD NUMEROUS CAUTION FLAGS, CREW RAN QRH WITH NO HELP DECIDED TO STOP CLIMB AT ABOUT FL280. THE PILOT DECLARED AN EMERGENCY AND BRIEFED FA AND PASSENGERS. CONTINUED ONTO PHX AND LANDED UNEVENTFULLY. NR 2 BATTERY WAS NEARLY DEAD, REPLACED BOTH MAIN BATTERIES BUT IT IS BELIEVED THIS WAS A RESULT OF POWER CONSUMPTION AFTER THE GENERATOR ISSUE AND NOT A CAUSE. FOUND A FUSE FOR THE ESS BUSS BAD AND REPLACED. TWO OTHER FUSES WERE FOUND WITH CORROSION AND REPLACED BUT WERE FUNCTIONAL AND NOT RELATED TO THE ORIGINAL ISSUE. BOTH #2 AND #4 GENERATORS WERE REPLACED AS WELL AS THEIR RESPECTIVE CONTROL UNITS. THE #2 GENERATOR WAS REPLACED A SECOND TIME AS IT WAS FOUND TO HAVE A BEARING FAIL MSG DISPLAYED DURING FOLLOW-ON OPS CHECKS. THE ELECTRICAL CONTROL PANEL WAS FOUND TO BE CAUSING AN ISSUE WITH THE ELECTRICAL ABNORMAL EMERGENCY OPS TEST AND WAS REPLACED. MANY OTHER OPS CHECKS AND A SUCCESSFUL CHECK FLIGHT WERE ALSO PERFORMED. STILL AWT ROOT CAUSE FROM MFR. ORIG SUB DATE: 4-25-2023.