What was found
RIGHT FIRE WARNING ILLUMINATED AND EXTINGUISHED WITH THE REDUCTION OF POWER. MAINTENANCE REMOVED THE COWLING AND INSPECTED THE ENGINE, FIRE LOOPS AND PLUMBING. NO DEFECTS WERE FOUND. ENGINE RUNS PERFORMED WITH NO DEFECTS FOUND. ALL FIRE LOOPS WERE DISCONNECTED FOR INSPECTION WITH NO DEFECTS FOUND. ALL FIRE LOOPS RUNG OUT WITH A MEGGER. THE HOT SECTION LOOP WAS FOUND TO HAVE 3.6 MEGAOHMS READING FOR INNER TO INNER AND .206 MEGAOHMS INNER TO OUTER. THIS IS OUT OF SPECIFICATION. HOT SECTION FIRE LOOP IS BEING REPLACED AND GROUND RUNS WILL BE PERFORMED. THIS DATA HAS BEEN FORWARDED TOP LEARJET ENGINEERING VIA THE JSLLC CAS REPORTING SYSTEM