What was found
CORROSION ON FLOORBEAM AT BS 727B AND RBL 24. REMOVED CORROSION, FLOORBEAM FOUND TO BE OUT OF LIMITS, FABRICATED REPAIR STRAP AND INSTALLED ALL REPAIR PARTS IAW SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM AT BS 727B AND RBL 24. REMOVED CORROSION, FLOORBEAM FOUND TO BE OUT OF LIMITS, FABRICATED REPAIR STRAP AND INSTALLED ALL REPAIR PARTS IAW SRM.