What was found
CORROSION ON FLOORBEAM AT BS 767 AT RBL 45. REMOVED CORROSION, AFTER CORROSION REMOVAL, DAMAGE FOUND TO BE OUT OF LIMITS. REMOVED CORRODED FLOORBEAM, AND FABRICATED REPAIR STRAPS AND INSTALLED STRAPS IAW CURRENT SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM AT BS 767 AT RBL 45. REMOVED CORROSION, AFTER CORROSION REMOVAL, DAMAGE FOUND TO BE OUT OF LIMITS. REMOVED CORRODED FLOORBEAM, AND FABRICATED REPAIR STRAPS AND INSTALLED STRAPS IAW CURRENT SRM.