Service difficulty report · Floor Support · Doug DC983

Difficulty date
November 19, 2012
Submitted
November 19, 2012
Operation
Air carrier
Aircraft
N120MN
Make and model
Doug DC983
Aircraft serial
53120
Aircraft time
40,084 hours, 41,076 cycles
Part
Floor Support
Condition
Corroded
Location
Zone 200
Part time
40,084 hours, 41,076 cycles
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFT FUSELAGE FLOOR STURCTURE AT BS 1309 HAS CORROSION ON UPPER SURFACE UNDER SMOKE TAPE BETWEEN RT AND LT HAT CHANNNELS. REMOVED CORROSION FROM FLOOR SUPPORT IAW SRM 51-10-3, FOUND TO BE OUT OF SRM LIMITS. FABRICATED REPAIR FLOOR SUPPORT REPAIR PARTS IAW SRM 51-10-4 PG 1-3. INSTALLED FLOOR SUPPORT IAW SRM 51-30-5.