What was found
LAV ACCESS SERVICE PANEL HAS CORROSION UNDER PAINT GBAMC NR 04161 AND NR 04185 UPON INVESTIGSTION FOUND SKIN TO BE OUT OF LIMITS BELOW LIP ON ACCESS DOOR, REMOVED DAMAGED SKIN AREA OF 1.75X9.00 FABED FILLER,FABED FINGER DOUBLER FOR BACK, FAB DOUBLER FOR EXTERNAL, INSTALLED SPLICE, INSIDE DOUBLER& OUTSIDE DOUBLER IAW COTNEY AEROSPACE DWG W93-RO3 REV.IR-CLOSED-