SDR 9501959754

Service difficulty report · Stall Transducer · Doug DC941

Difficulty date
February 7, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N754NW
Make and model
Doug DC941
Aircraft serial
47178
Part
Stall Transducer
Condition
Failed
Location
Right
Stage of operation
CL
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

STALL INDICATION FAILURE LIGHT ILLUMINATED AFTER TAKEOFF WHEN FLAPS AND SLATS WERE RETRACTED. PERFORMED PRECAUTIONARY FLIGHT PROCEDURES AND NR 2 SYSTEM TESTED BAD. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. REPLACED THE RIGHT STALL WARNING TRANSDUCER AND TONE GENERATOR. OPERATIONAL CHECK OK. AIRCRAFT RETURNED TO SERVICE.