SDR 9505169861

Service difficulty report · Control Unit · Doug DC951

Difficulty date
March 31, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N770NC
Make and model
Doug DC951
Aircraft serial
47758
Part
Control Unit
Condition
Malfunctioned
Location
Right
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT ICE PROTECTION TEMPERATURE LOW LIGHT REMAINED ON AFTER TAKEOFF. LIGHT EXTINGUISHED AFTER WORKING WITH CROSSFEED. LEFT SUPPLY TEMPERATURE HIGH LIGHT THEN ILLUMINATED. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. REPLACED THE RIGHT THERMAL CONTROL UNIT AND RIGHT LOW TEMPERATURE SENSOR. OPERATIONAL CHECK OK, AND AIRCRAFT RETURNED TO SERVICE.

More about the Doug DC-9-51