What was found
DURING INTERMEDIATE LAYOVER VISIT, FOUND CORROSION ON THE RIVETS COMMON TO STR 44 BETWEEN FRAMES 33 AND 34. AFTER REMOVING THE RIVETS, THE STRINGER REVEALED CORROSION ON THE UPPER SURFACE OF THE STRINGER FLANGE COMMON TO THE FUSELAGE SKIN. REPAIRED PER NWA EA 32-97859.