What was found
DURING H-CHECK, FOUND LEFT OVERWING EMERGENCY EXIT DOOR CRACKED AT AFT LOCKING PIN FLANGE. REPAIRED CRACK PER SRM 52-05 FIG 51 VIEW H. PERMANENT REPAIR WILL BE ACCOMPLISHED AT NEXT PERIODIC CHECK.