SDR 9514099102

Service difficulty report · Transfer Relay · Doug DC915

Difficulty date
September 8, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N92S
Make and model
Doug DC915
Aircraft serial
47064
Part
Transfer Relay
Part number
92057802
Condition
Malfunctioned
Location
Dc Emergency Pwr
Stage of operation
CL
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER TAKEOFF, BOTH A AND B PHASE FUEL BOOST PUMP CIRCUIT BREAKERS POPPED, IN CONJUNCTION WITH LOSS OF SEVERAL AIRCRAFT COMPONENTS INCLUDING COMMUNICATIONS. FLIGHT RETURNED TO DTW AND LANDED WITHOUT INCIDENT. REPLACED DC CROSSTIE RELAY (R2-27) AND NR 1 AND NR 2 TRANSFORMER RECTIFIERS. ALSO, SWAPPED GENERATOR CONTROL PANELS, ALL WITH NO HELP. REPLACED DC EMERGENCY POWER TRANSFER RELAY (R2-19). SYSTEM CHECKED OK AND AIRCRAFT RETRUNED TO SERVICE.