What was found
CRACK INDICATION IN THE FIRST AND SECOND FASTENER HOLES BELOW THE FLOOR IN THE R/T FRAME AT BS 848.5. REPAIRED R/T FRAME AT BS 848.5 IAW FEDEX EA 7-5310-24522.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK INDICATION IN THE FIRST AND SECOND FASTENER HOLES BELOW THE FLOOR IN THE R/T FRAME AT BS 848.5. REPAIRED R/T FRAME AT BS 848.5 IAW FEDEX EA 7-5310-24522.