What was found
DOUBLE HOLE IN LOWER CHORD OF FLOORBEAM BS 720F LBL 46 WL 201. OVERSIZED HOLE AND INSTALLED HI-LOC PER ENGINEERING REQUEST.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DOUBLE HOLE IN LOWER CHORD OF FLOORBEAM BS 720F LBL 46 WL 201. OVERSIZED HOLE AND INSTALLED HI-LOC PER ENGINEERING REQUEST.