What was found
CORROSION (72C237-02), ON TOP CHORD OF BS 1030 FLOORBEAM RBL 9 TO 22 LBL 51.5 WL 208. MECHANICALLY REMOVED CORROSION FROM TOP CHORD OF FLOORBEAM AT BS 1030 RBL 9 TO 22 LBL 51.5 AREA WAS OUT OF LIMITS PER FEDEX SRM 53-10-1. REPAIRED TOP CHORD OF FLOORBEAM AT BS 1030 LBL 51.5 WL 208 PER FEDEX EA 7-5310-25603.