What was found
CORROSION FWD BAY ON STR CLIP AT BS 660 STR 26R ON BILGE. REMOVED STR CLIP AT BS 660 STR 26R AND FOUND CORROSION OUT OF LIMITS PER FEDEX SRM 53-10-1. INSTALLED FAB STR CLIP AT BS 660 STR 26R.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION FWD BAY ON STR CLIP AT BS 660 STR 26R ON BILGE. REMOVED STR CLIP AT BS 660 STR 26R AND FOUND CORROSION OUT OF LIMITS PER FEDEX SRM 53-10-1. INSTALLED FAB STR CLIP AT BS 660 STR 26R.