What was found
CORROSION IN FWD BAY, BS 700 STR 28 LT AND RT WL 148 ON THE SHEAR TIE. REPLACED SHEAR TIE AT BS 700 STR 28 LT AND RT WL 148 PER FEDEX SRM 53-10-4. THE CORROSION REMOVED WAS FOUND TO BE OUT OF LIMITS PER FEDEX SRM 53-10-1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION IN FWD BAY, BS 700 STR 28 LT AND RT WL 148 ON THE SHEAR TIE. REPLACED SHEAR TIE AT BS 700 STR 28 LT AND RT WL 148 PER FEDEX SRM 53-10-4. THE CORROSION REMOVED WAS FOUND TO BE OUT OF LIMITS PER FEDEX SRM 53-10-1.