What was found
CRACK IN FRAME EMANATING FROM TOOLING HOLE AT BS 312 LBL 47 WL 175. REMOVED CRACKED FRAME AT BS 312 LBL 47 WL 175. RELEVELED NEW FRAME, DRILLED, ALODINED, PRIMED AND INSTALLED PER FEDEX SRM 51-20-1, 51-10-02, 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK IN FRAME EMANATING FROM TOOLING HOLE AT BS 312 LBL 47 WL 175. REMOVED CRACKED FRAME AT BS 312 LBL 47 WL 175. RELEVELED NEW FRAME, DRILLED, ALODINED, PRIMED AND INSTALLED PER FEDEX SRM 51-20-1, 51-10-02, 51-30-02.