What was found
STR 22R PUNCTURED BS 480 PLUS 8.5 INCHES. REMOVED DAMAGED SECTION OF STR 22R, BS 480 PLUS 8.5 INCHES. FABRICATED REPAIR PARTS AND INSTALLED WET WITH SEALANT IAW FEDEX 727 SRM 53-10-3, FIG 1.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STR 22R PUNCTURED BS 480 PLUS 8.5 INCHES. REMOVED DAMAGED SECTION OF STR 22R, BS 480 PLUS 8.5 INCHES. FABRICATED REPAIR PARTS AND INSTALLED WET WITH SEALANT IAW FEDEX 727 SRM 53-10-3, FIG 1.