What was found
MECH DAMAGE FOUND ON STR CLIP AND AT STA 750F, STR 7R. REMOVED DAMAGED STR CLIP AT STA 950F, STR 7R. BACK DRILLED NEW CLIP AND INSTALLED WET WITH FAYING SURFACE SEALANT IAW FEDEX SRM 51-30-2, 51-10-1, MM 51-30-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MECH DAMAGE FOUND ON STR CLIP AND AT STA 750F, STR 7R. REMOVED DAMAGED STR CLIP AT STA 950F, STR 7R. BACK DRILLED NEW CLIP AND INSTALLED WET WITH FAYING SURFACE SEALANT IAW FEDEX SRM 51-30-2, 51-10-1, MM 51-30-0.