What was found
FRAME BENT WITH POSSIBLE CRACK AT BS 520 STR 25R. CUT OUT DAMAGE, FABRICATED DOUBLER AND INSTALLED PER FEDEX SRM 51-40-03.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FRAME BENT WITH POSSIBLE CRACK AT BS 520 STR 25R. CUT OUT DAMAGE, FABRICATED DOUBLER AND INSTALLED PER FEDEX SRM 51-40-03.