What was found
WORKING FASTENERS AT BS 1342.4 STR 8 TO 12R. CUT OUT DAMAGE SKIN, FABRICATED FILLERS AND DOUBLERS. ALODINED AND PRIMED SEALED AND INSTALLED WITH FASTENERS WET WITH SEALANT PER FEDEX SRM 54-30-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
WORKING FASTENERS AT BS 1342.4 STR 8 TO 12R. CUT OUT DAMAGE SKIN, FABRICATED FILLERS AND DOUBLERS. ALODINED AND PRIMED SEALED AND INSTALLED WITH FASTENERS WET WITH SEALANT PER FEDEX SRM 54-30-3.