What was found
CORROSION (C53-229-01(1) FLOOR BEAM STA 344, LBL 3-58, WL 208.1, UPPER SURFACE OF TOP CHORD, RBL 0-42, WL 208, LOWER SURFACE OF TOP CHORD. TOP CHORD OF THE FLOOR BEAM AT BS 344 WAS FOUND TO BE OUT OF LIMITS IAW FEDEX SRM 53-10-1. REPAIRED FLOOR BEAM AT BS 344 IAW FEEX DRAWING SR 27-53-007.