What was found
SEA - DURING MAINTENANCE CHECK, THE EMERGENCY EXIT FLOOR TRACK LIGHTS WERE FOUND INOPERATIVE AT ROWS 12 THROUGH 16 AND ROW 27 AFT. SPLICED BROKEN WIRES AT ROWS 14-15, AND RECONNECTED LOOSE CONNECTORS AT ROWS 13, 27 AND AT THE AFT LAVATORY DOOR. REFERENCE ASAA9540050.