What was found
SPLICE FITTING AT FS 1050 ON TOP SIDE OF L-31R HAS LEVEL 2 CORROSION. REMOVED SPLICE FITTING. REMOVED LIGHT CORROSION FROM AREA. DRILLED NEW FITTING. TREATED, PRIMED, AND INSTALLED FITTING IAW SRM 51-1-8 AND 51-1-20A. AREA UNDER FITTING WITHIN LIMITS IAW 53-2-0.