What was found
PHX - DURING ACCOMPLISHMENT OF LOWER LAP SKIN INSPECTION PER BSB 737 53A1177, SKIN CRACKS WERE IDENTIFIED AT BS 845 STR 4L, .125 INCHES IN LENGTH. ALL AREAS WERE REPAIRED IAW AWA EO 53-30-16 AND ER 2-53-33-08. REF 95ZZZW197, 95ZZZW199, 95ZZZW200, AWXA9500093.