What was found
STL - DURING CLIMB, NR 3 ENGINE FIREWARNING SOUNDED. REDUCED POWER ON THE NR 3 ENGINE AND FIREWARNING CEASED. FOUND 13TH STAGE DUCT AND PERFORMED A HIGH POWER LEAK CHECK. CHECKED NORMAL. CHECK C-1 11-21-94 - MCI.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STL - DURING CLIMB, NR 3 ENGINE FIREWARNING SOUNDED. REDUCED POWER ON THE NR 3 ENGINE AND FIREWARNING CEASED. FOUND 13TH STAGE DUCT AND PERFORMED A HIGH POWER LEAK CHECK. CHECKED NORMAL. CHECK C-1 11-21-94 - MCI.