DURING D-CHECK, FOUND CORROSION ON 'T' ANGLE FLOOR SUPPORT RBL 41 JUST FWD OF STA 312 FLOORBEAM. REPLACED ANGLE AND INSTALLED PER SRM 51-10-1 PG 4 AND 5, 51-30-2. TOTAL CYCLES 29577.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, FOUND CORROSION ON 'T' ANGLE FLOOR SUPPORT RBL 41 JUST FWD OF STA 312 FLOORBEAM. REPLACED ANGLE AND INSTALLED PER SRM 51-10-1 PG 4 AND 5, 51-30-2. TOTAL CYCLES 29577.