What was found
DURING D-CHECK, STA 314 FLOOR SUPPORT IS CORRODED FROM RBL 15 TO RBL 42. INSTALLED NEW SUPPORT ANGLE AS PER SRM 57-10-1 PAR 4 AND SRM 51-30-2 FROM RBL 15 - RBL 42 7075-T73 STA 314. TOTAL CYCLES 29577.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, STA 314 FLOOR SUPPORT IS CORRODED FROM RBL 15 TO RBL 42. INSTALLED NEW SUPPORT ANGLE AS PER SRM 57-10-1 PAR 4 AND SRM 51-30-2 FROM RBL 15 - RBL 42 7075-T73 STA 314. TOTAL CYCLES 29577.