What was found
DURING D-CHECK, CORROSION ON STRINGER 30 BETWEEN BS 1030 AND BS 1050, ALSO SKIN SURFACE ADJACENT TO STRINGER. REMOVED FASTENERS PER SRM 51-30-2. REMOVED CORROSION PER SRM 51-10-6, TREATED AND PRIMED PER SRM 51-10-2. REPLACED PARTS (FAB) PER SRM 51-10-1, SEALED AREA PER SRM 51-20-4, INSTALLED FASTENERS AND PARTS PER SRM 51-30-2, MATERIAL 2.5 INCHES BY 9 INCHES 2024-T3 .063. TOTAL CYCLES 29,235. (W)