What was found
DURING D-CHECK, AFT CARGO RT STATION 1030-1050 STRINGER 25R INTERCOSTAL IS BENT AND CRACKED. STOP DRILLED CRACK AS PER SRM 51-10-1, INSTALLED DOUBLER AS PER SRM 51-40-2 2024-T3 .050 4.5 INCH BY 5.5 INCH. TOTAL CYCLES 29,235. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, AFT CARGO RT STATION 1030-1050 STRINGER 25R INTERCOSTAL IS BENT AND CRACKED. STOP DRILLED CRACK AS PER SRM 51-10-1, INSTALLED DOUBLER AS PER SRM 51-40-2 2024-T3 .050 4.5 INCH BY 5.5 INCH. TOTAL CYCLES 29,235. (W)