What was found
DURING D-CHECK, FORWARD CARGO DOOR CUT OUT, AFT BOTTOM CORNER 'L' ANGLE HAS CORROSION, LOCATED JUST ABOVE TIE DOWN STATION 620 STRINGER 26R. FABRICATED NEW 'L' ANGLE PER SRM 51-10-5 .063 2024-T3 2 INCH BY 1 INCH BY 2 INCH. TREATED AND PRIMED PER SRM 51-10-2 AND INSTALLED PER SRM 51-40-3. TOTAL CYCLES 29,235. (W)