As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING D-CHECK, FRAME UPPER FLANGE CRACKED BS 620 BETWEEN STRINGER 28L NUMEROUS AREAS. REMOVED FASTENERS PER SRM 51-30-2. CUT OUT DAMAGED AREA (3 PLACES) PER SRM 53-10-4 FIG 1. INSTALLED FRAME AND REPAIR AND PER SRM 53-10-4 FIG 1 AND SRM 51-30-2. SIZE 24 INCHES BY 3 INCHES. TOTAL CYCLES 29235.