What was found
DURING D-CHECK, AREA EXPOSED BY REMOVAL OF ACCESS PANEL 1104, APPROX BET BS 330 TO 350 FRAME AT APPROX BS 350 HAS EXFOLIATION OF FWD FRAME (APPROX BR 3 INCHES TO BLL 10 INCHES), CORROSION AROUND FASTENERS, CORROSION AT LONG FASTENERS (LT AND RT), CORROSION AT AND AROUND FASTENERS AND HORIZ PLATE. REMOVED CORROSION PER SRM 51-10-6, CUT OUT DAMAGED AREA BS 350 PER SRM 51-40-2, ALODINE AND PRIMED PER SRM 51-10-2, INSTALLED WEB REPAIR PER SRM 51-40-2 AND FASTENERS PER SRM 51-10-1. SIZE 4 INCHES BY 11 INCHES. TOTAL CYCLES 29235.