What was found
DURING D-CHECK, FLOOR BOARD ATTACHMENT ANGLE RBL 64 BS 380 TO BS 420 HAS CORROSION TOP AND BOTTOM SIDES. REMOVED ANGLE PER SRM 51-30-2. REMOVED CORROSION AROUND ANGLE AREA PER SRM 51-10-6. MATERIAL LOSS 0.002, FABRICATED ANGLE PER SRM 51-10-1 2024-T3 .063. TOTAL CYCLES 29235.