What was found
DURING D-CHECK, UPPER LOBE STA 804 STR 14R, CRACK IN FRAME, STOP DRILLED PER SRM 51-10-1. INSTALLED ANGLE REPAIR AS PER SRM 51-40-3 SIZE 1 INCH BY 1 INCH BY 9 INCH MAT 7075-T6 .071. TOTAL CYCLES 29235.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.