What was found
DURING D-CHECK, UPPER LOBE STA 720F STR 15F, CRACKED AT FRAME. STOP DRILLED PER SRM 51-10-1. INSTALLED ANGLE REPAIR AS PER SRM 51-40-3 7075-T6 .071 1 INCH BY 1 INCH BY 10 INCH. TOTAL CYCLES 29235.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D-CHECK, UPPER LOBE STA 720F STR 15F, CRACKED AT FRAME. STOP DRILLED PER SRM 51-10-1. INSTALLED ANGLE REPAIR AS PER SRM 51-40-3 7075-T6 .071 1 INCH BY 1 INCH BY 10 INCH. TOTAL CYCLES 29235.