DURING D-CHECK, CABIN INTERIOR HAS SURFACE CORROSION ON I/B AND O/B SIDES OF CABIN FLOOR ANGLE AT FS 370, AT APPROX STR 17R. REMOVED ANGLE PER SRM 51-30-2. REMOVED CORROSION AROUND ANGLE AREA PER SRM 51-10-6. MAT LOSS 0.002, FABRICATED ANGLE PER SRM 51-10-1 MAT .2024-T3 .063 84 INCHES BY 63 INCHES. TOTAL CYCLES 29235.