What was found
OXYGEN PASSENGER BOTTLE S/N 101 (CONTROL HEAD S/N) HAS ITS MASK HOSE KINKED AND OXYGEN WILL NOT FLOW TO THE MASK. REMOVED AND REPLACED OXYGEN MASK ASSY. OPS CHECKED OK AT THIS TIME. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
OXYGEN PASSENGER BOTTLE S/N 101 (CONTROL HEAD S/N) HAS ITS MASK HOSE KINKED AND OXYGEN WILL NOT FLOW TO THE MASK. REMOVED AND REPLACED OXYGEN MASK ASSY. OPS CHECKED OK AT THIS TIME. (W)