What was found
LEVEL 2 CORROSION, AFT CABIN FLOOR BEAM CAP AT BS 1540 IS CORRODED FROM 45 INCHES LBL TO 45 INCHES. REMOVED AND REPLACED FLOOR BEAM CAP PER SRM 53-1-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION, AFT CABIN FLOOR BEAM CAP AT BS 1540 IS CORRODED FROM 45 INCHES LBL TO 45 INCHES. REMOVED AND REPLACED FLOOR BEAM CAP PER SRM 53-1-0.